Contact us.

H.E.A.T. 800-524-4280
Heatingprosnyc@gmail.com
NYC- Connecticut

Daikin Rebel

Rebel Rooftop Unit Integrated Intel Technology to Drive Internet of Things Daikin Applied is making use of the Internet of Things (IoT) through the integration of an Intel-based intelligent gateway solution in its existing Rebel rooftop units. With the Intel-based intelligent gateway solution, Daikin Applied is able to seamlessly connect Rebel units to the cloud […]

Read More »

Dielectric Unions

Series 3001A Dielectric Unions are used in commercial and residential applications to prevent accelerated corrosion and deterioration in the piping system due to galvanic and stray current. It is installed between pipes made from dissimilar metals, and features a female iron pipe thread to solder connection. It consists of a union nut, two tailpieces, and […]

Read More »

Updated Local Law 84 Applcation Information, Fall, 2013

Below is an email we just received from NYC’s department of buildings, Greener-greater-buildings-plan.   A city agency promoting energy efficiency improvements, and providing information about important issues with benchmarking requirements that have taken affect.  We are re-publishing it here because it’s important information and many NYC buildings owners do not get these types of emails because they […]

Read More »

Benchmarking Compliance NYC

Benchmarking Compliance NYC If you own a building you may assign a representative in consultation with the building’s operating staff to benchmark your building’s energy use. When benchmarking is complete, you must electronically submit the report generated by the EPA’s online tool – Portfolio Manager. Submit your report the results to the Department of Finance […]

Read More »

Two stage boiler stack economizer

Two Stage Boiler Stack Economizer The 2 stage boiler stack economizer is perfect for any NYC building with a heating system of 150HP or larger. In short, a 2 stage boiler stack economizer is one energy saving device that pre-heats 2 different water applications. 1) The two stage economizer’s first (noncondensing) stage, heats the water […]

Read More »

Navien Service & Repair NYC

Navien Service & Repair NYC We repair & service the complete Navien product line.  800.524.4280 We hope your Navien product was installed correctly by a licensed plumber, with additional training and certified by Navien.  If not, we offer tankless water heater repair services. Our installers are certified, factory training Navien technicians. If your plumber cut […]

Read More »

NYC Energy Audit Options

Why Choose An Energy Audit With H.E.A.T.? H.E.A.T. offers a variety of energy audits to suit the needs of your building. We recommend the Level 2 Energy Audit to many of our clients (with a building larger than 50,000 square feet) in order to comply Local Law 87 and get access to financial incentives offered for […]

Read More »

Boiler Economizer History

Boiler Economizer History Source: http://en.wikipedia.org/wiki/Economizer The first successful economizer design was used to increase the steam-raising efficiency of the boilers of stationary steam engines. It was patented by Edward Green in 1845, and since then has been known as Green’s economizer. It consisted of an array of vertical cast iron tubes connected to a tank […]

Read More »

CHP Success Story- Bronx

CHP Success Story- Bronx A CHP at Co-op City marks huge energy savings success. Information sited:  NYSERDA 2012-2013 Annual Report   [PDF|3.14 MB] Co-op City, a 15,000-unit apartment complex with 60,000 residents in the Bronx The Co-op city complex is supported by an on-site 40 MW Combined Heat and Power (CHP) system that provides heating, cooling, […]

Read More »

Changing from Oil to Natural Gas in NYC.

Changing from Oil to Natural Gas in NYC. So you are ready to save tens of thousands per year on your building’s heating expenses?  Need a quote for converting your Manhattan buildings heating system from heating oil to natural gas?  Give us a call to schedule an appointment today.  We’re New York City’s Midtown- Bronx […]

Read More »

Flash Tank Heat Recovery

Flash Tank Heat Recovery Heat Recovery Systems In addition to the heat recovered as flashed steam, the heat exchanger will transfer the remaining heat normally lost during  blow down to the cold makeup water as it flows to the feedwater heater. The systems quickly pay for themselves with fuel savings resulting from recycled heat that […]

Read More »

What is a NYSERDA MPP partner?

New York State Energy Research Development Authority-  Multifamily Performance Partner, or NYSERDA MPP for short. MPP Partners are an essential element of NYSERDA’s Multifamily Performance Program (MPP), which provides incentives to help residential building owners, developers and condo/co-op boards, and facility managers improve the energy efficiency of their buildings.  For MPP participants, MPP partners are […]

Read More »

Steam System Deaerator

Steam System Deaerator What is a steam deaerator? A deaerator is a device used to removal of oxygen and other dissolved gases from the feedwater for steam-generating boilers.  In particular, dissolved oxygen in boiler feedwater will cause serious corrosion damage in steam systems by attaching to the walls of metal piping and other metallic equipment […]

Read More »

Never Forget

WE WILL NEVER FORGET- High Efficiency Application Technology’s owners and staff are passionate about New York City, People, the Earth.  The years pass by the memory is still as vivid as ever, and it’s affects on the world are still being realized.  The staff at HEAT is a close group, we still pray for all […]

Read More »

Jack Shaft Upgrade

Jack Shaft Boiler Upgrades Boiler Efficiency Improvement through Linkageless Control A “jack shaft” system is inefficient and wastes energy, Jack Shafts are older mechanical linkage systems that control the fuel and air combustion entering a burner. Many boiler burners are controlled by a single modulating motor with jackshafts to the fuel valve and air damper […]

Read More »